    ISO 10993-1:2025

    Biological evaluation of medical devices — Part 1: Requirements and general principles for the evaluation of biological safety within a risk management process
    • 발행일 : 2025-11-18
    • 발행기관 : ISO
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]PDF 330,800원

    • [영어]PRINT 330,800원

상세정보

분야 ISO/TC 194 : Biological and clinical evaluation of medical devices
적용범위

This document specifies the requirements and general principles governing the biological evaluation of medical devices within a risk management process according to ISO 14971.

This document applies to the biological evaluation of medical devices that have direct contact or indirect contact with either:

—     a patient's body during intended use or reasonably foreseeable misuse; or

—     the body of other users who are not patients, if the medical device is intended for personal protection (e.g. medical gloves, surgical masks).

Biological evaluation assesses the biological safety of the medical device by considering the biological risks associated with:

—     constituents of a medical device; and

—     tissue-device interactions (including physical effects).

The biological evaluation specified in this document can address the biological safety of the medical device, considering the life cycle from design and development through initial use of the finished medical device to final decommissioning or withdrawal from use. The biological evaluation considers both the biological safety of the finished device in first use, and the significance of any changes to the medical device which can occur throughout the life cycle. However, the evaluation of risks related to environmental impacts of decommissioning of medical devices are not within the scope of this document. This document does not mandate re-testing of medical devices that are already on the market and have established and acceptable safety profiles (see 6.6.2).

This document can be useful to support clinical or usability evaluations of medical devices. For example, a biological evaluation is a pre-requisite for conducting a clinical trial. This means that principles outlined in this document can be applied to the evaluation of prototype or development stage devices, as well as to finished medical devices.

Other parts of the ISO 10993 series cover specific aspects of biological evaluation, such as chemical characterization, biological testing, sample preparation, animal welfare and toxicological risk assessment.

For some types of medical devices, specific requirements from other standards (outside the ISO 10993 series) can be considered with a justification for the approach taken if there are differences between the requirements of the ISO 10993 series and those provided in other standards. For example, the ISO 18562 series provides specific requirements for biological evaluation of breathing gas pathway medical devices and ISO 7405 provides specific requirements for biological evaluation of dental devices.

The evaluation of risks related to infectious agents [e.g. bacteria, moulds, yeasts, viruses, transmissible spongiform encephalopathy (TSE) agents] is not within the scope of this document.

NOTE 1        The evaluation of bacterial endotoxins is addressed by ISO 11737-3.

NOTE 2        The evaluation of risks related to viruses, TSE agents and other pathogens originating from materials of animal origin is addressed by the ISO 22442 series.

국제분류(ICS)코드 11.100 : 약실험
11.100.20 : 의료 장비의 생물학적 평가
페이지수 42
Edition 6

이력정보

No. 표준번호 표준명 발행일 상태
1 ISO 10993-1:2025상세보기 Biological evaluation of medical devices — Part 1: Requirements and general principles for the evaluation of biological safety within a risk management process 2025-11-18 표준
2 ISO 10993-1:2018상세보기 Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process 2018-08-17 구판
3 ISO 10993-1:2009/Cor 1:2010상세보기 Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process — Technical Corrigendum 1 2010-06-04 구판
4 ISO 10993-1:2009상세보기 Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process 2009-10-13 구판
5 ISO 10993-1:2003상세보기 Biological evaluation of medical devices — Part 1: Evaluation and testing 2003-07-28 구판
6 ISO 10993-1:1997상세보기 Biological evaluation of medical devices — Part 1: Evaluation and testing 1997-12-11 구판
7 ISO 10993-1:1992/Cor 1:1992상세보기 Biological evaluation of medical devices — Part 1: Guidance on selection of tests — Technical Corrigendum 1 1992-09-09 구판
8 ISO 10993-1:1992상세보기 Biological evaluation of medical devices — Part 1: Guidance on selection of tests 1992-04-23 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)
  • PDF+PRINT :

    직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)
  • 보안PDF+PRINT :

    직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • ASME PBVC Plus :

    인쇄본 우편발송 및 온라인 구독(1User용, 2년)