QUICK

TOP

해외표준 상세정보

관심표준 등록 : 표준업데이트 시 알림서비스

제공형태 더보기
  • 표준

    판매

    IEC 60664-4:2005

    Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress
    • 발행일 : 2005-09-15
    • 발행기관 : IEC
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어/불어]PDF 622,500원

    • [영어/불어]PRINT 622,500원

상세정보

분야 TC 109 : Insulation co-ordination for low-voltage equipment
적용범위 IEC 60664-4:2005 Deals with basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment. The dimensioning values directly apply for basic insulation; for reinforced insulation additional requirements apply according to Part 1. It is applicable for the dimensioning of clearances, creepage distances and solid insulation stressed by any type of periodic voltages with a fundamental frequency above 30 kHz and up to 10 MHz. This part of IEC 60664 can only be used together with IEC 60664-1 or with IEC 60664-5 (in this standard called Part 1 or Part 5). By using Part 1 or Part 5 together with this part the frequency limit of Part 1 or Part 5 is extended to frequencies higher than 30 kHz. This part also applies to Part 3 for frequencies greater than 30 kHz and protection of type 1. For type 2 protection this question is under consideration. Applies to equipment for use up to 2 000 m above sea level having a rated voltage up to a.c. 1 000 V. Specifies the requirements for clearances, creepage distances and solid insulation for equipment based upon their performance criteria. lt includes methods of electric testing with respect to insulation coordination. The minimum clearances specified in this part do not apply where ionized gases occur. Special requirements for such situations may be specified at the discretion of the relevant technical committee. This part does not deal with distances
- through liquid insulation,
- through gases other than air,
- through compressed air.
The object of this standard is to guide technical committees responsible for different equipment in order to rationalise their requirements so that insulation coordination is achieved when specifying clearances in air, creepage distances and solid insulation for equipment. The major changes made during the revision of IEC 60664-4 were the following:
- inclusion of more recent information about the withstand characteristics of insulation at high-frequency voltage stress (see Annexes A, B and C);
- inclusion of requirements for the dimensioning of clearances at high-frequency voltage stress (see Clause 4);
- inclusion of requirements for the dimensioning of creepage distances at high-frequency voltage stress (see Clause 5);
- inclusion of requirements for the dimensioning of solid insulation at high-frequency voltage stress (see Clause 6);
- inclusion of diagrams to provide guidance on dimensioning with respect to high-frequency voltage stress (see Annex F);
specification of tests with respect to high-frequency voltage stress (see Clause 7);
- inclusion of test circuits for high-frequency voltage withstand testing and partial discharge testing (see Annex D.1 and D.2.1);
- inclusion of design criteria for partial discharge test circuits at high-frequency voltage (see Annex D.2.2);
- inclusion of criteria for dealing with non sinusoidal voltage stress (see Clause 8 and Annex E).
국제분류(ICS)코드 29.080.30 : 절연 시스템
페이지수 135
Edition 2.0

이력정보

No. 표준번호 표준명 발행일 상태
1 IEC 60664-4:2005상세보기 Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress 2005-09-15 표준
2 IEC TR 60664-4:1997상세보기 Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress 1997-09-10 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)